Universal AC/DC Transmitter RR-5M6SHE6KD

  • Measures AC current and voltage signals
  • Outputs passive or active current signals
  • Programming, process monitoring and diagnostics via PR 4500
  • Response time < 0.75 s and excellent accuracy better than 0.3%
  • Universally powered by 21.6…253 VAC / 19.2…300 VDC

Description

  • Application

    • The 0…5 AAC RMS range makes it possible to accurately measure a typical current transformer.
    • The 0…300 VAC RMS range allows accurate supply voltage monitoring.
    • The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
    • Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0…1 VAC RMS input = ±10 volt or 4…20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
    • Configurable input limits control the output value for increased safety.
    • The 4179 provides the required failure data (SFF and PFDAVG) for SIL 2 applications as per IEC 61508 / IEC 61511.
    • Failure rates for 4179 correspond to Performance Level “d” according to ISO-13849.

    Technical characteristic

    • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
    • Possibility of output safety feedback by selecting S4…20 mA output.
    • The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
    • Exceptional mA output load stability of <0.001% of span / 100 Ohm.
    • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
    • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
    • Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
    • Excellent signal to noise ratio of > 60 dB.

    Mounting / installation / programming

    • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
    • Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.

Reviews

There are no reviews yet.

Be the first to review “Universal AC/DC Transmitter RR-5M6SHE6KD”

Your email address will not be published. Required fields are marked *

Description

  • Application

    • The 0…5 AAC RMS range makes it possible to accurately measure a typical current transformer.
    • The 0…300 VAC RMS range allows accurate supply voltage monitoring.
    • The 4179 measures standard input ranges, and can be freely configured to customer-defined input range.
    • Converts narrow AC current / voltage inputs to wide bipolar or unipolar outputs, e.g. 0…1 VAC RMS input = ±10 volt or 4…20 mA output with a minimum span of 0.5 AAC RMS or 0.5 VAC RMS.
    • Configurable input limits control the output value for increased safety.
    • The 4179 provides the required failure data (SFF and PFDAVG) for SIL 2 applications as per IEC 61508 / IEC 61511.
    • Failure rates for 4179 correspond to Performance Level “d” according to ISO-13849.

    Technical characteristic

    • The latest analog and digital techniques are used to obtain maximum accuracy and immunity to interference.
    • Possibility of output safety feedback by selecting S4…20 mA output.
    • The current output can drive up to 800 Ohms, with an adjustable response time of 0.0…60.0 seconds.
    • Exceptional mA output load stability of <0.001% of span / 100 Ohm.
    • Meets the NAMUR NE21 recommendations, ensuring high accuracy in harsh EMC environments.
    • Meets the NAMUR NE43 recommendations, allowing the control system to easily detect an input error.
    • Tested to a high 2.3 kVAC, 3-port galvanic isolation level.
    • Excellent signal to noise ratio of > 60 dB.

    Mounting / installation / programming

    • Very low power consumption means units can be mounted side by side without an air gap – even at 60°C ambient temperature.
    • Configuration, monitoring, 2-point process calibration and more are accomplished using PR’s 4500 series of detachable displays.

Reviews

There are no reviews yet.

Be the first to review “Universal AC/DC Transmitter RR-5M6SHE6KD”

Your email address will not be published. Required fields are marked *

Universal AC/DC Transmitter RR-5M6SHE6KD

  • Measures AC current and voltage signals
  • Outputs passive or active current signals
  • Programming, process monitoring and diagnostics via PR 4500
  • Response time < 0.75 s and excellent accuracy better than 0.3%
  • Universally powered by 21.6…253 VAC / 19.2…300 VDC
Scroll to Top